dc.description.abstractA helium beam path for the marresearch imaging plate detector system (X-ray Research GmbH, Norderstedt, Germany) is described. The helium beam path is designed to minimize unwanted air scattering of the primary beam and to reduce absorption of the diffracted beam. The standard marresearch detector system, consisting of the imaging plate detector (online scanner) and the detector base with integrated collimation system, remains unchanged. The beam path consists of a polyethylene bag with the open end fixed to a metal ring. The ring is pressed against the entry window of the imaging plate detector. In this way a sealed volume is created. The primary beam enters into the helium bag through an additional collimating system which is sealed with a thin polyimide window. The crystal and the goniometer head are located inside the helium bag and are connected to the outside spindle axis via a linear and rotary motion feedthrough.de_CH
dc.language.isoende_CH
dc.publisherWileyde_CH
dc.relation.ispartofJournal of Applied Crystallographyde_CH
dc.rightsLicence according to publishing contractde_CH
dc.subjectImaging platede_CH
dc.subjectHelium beam pathde_CH
dc.subjectDiffractionde_CH
dc.subject.ddc540: Chemiede_CH
dc.titleA helium beam path for an imaging-plate detector systemde_CH
dc.typeBeitrag in wissenschaftlicher Zeitschriftde_CH
dcterms.typeTextde_CH
zhaw.departementSchool of Engineeringde_CH
dc.identifier.doi10.1107/S0021889897005773de_CH
zhaw.funding.euNode_CH
zhaw.issue30de_CH
zhaw.originated.zhawNode_CH
zhaw.pages.end1166de_CH
zhaw.pages.start1165de_CH
zhaw.publication.statuspublishedVersionde_CH
zhaw.volume1997de_CH
zhaw.publication.reviewPeer review (Publikation)de_CH
Appears in collections:Publikationen School of Engineering

Files in This Item:
There are no files associated with this item.
Show simple item record
Estermann, M. A., Scheidegger, S., Reifler, H., & Steurer, W. (1997). A helium beam path for an imaging-plate detector system. Journal of Applied Crystallography, 1997(30), 1165–1166. https://doi.org/10.1107/S0021889897005773
Estermann, M.A. et al. (1997) ‘A helium beam path for an imaging-plate detector system’, Journal of Applied Crystallography, 1997(30), pp. 1165–1166. Available at: https://doi.org/10.1107/S0021889897005773.
M. A. Estermann, S. Scheidegger, H. Reifler, and W. Steurer, “A helium beam path for an imaging-plate detector system,” Journal of Applied Crystallography, vol. 1997, no. 30, pp. 1165–1166, 1997, doi: 10.1107/S0021889897005773.
ESTERMANN, Michael A., Stephan SCHEIDEGGER, Hans REIFLER und Walter STEURER, 1997. A helium beam path for an imaging-plate detector system. Journal of Applied Crystallography. 1997. Bd. 1997, Nr. 30, S. 1165–1166. DOI 10.1107/S0021889897005773
Estermann, Michael A., Stephan Scheidegger, Hans Reifler, and Walter Steurer. 1997. “A Helium Beam Path for an Imaging-Plate Detector System.” Journal of Applied Crystallography 1997 (30): 1165–66. https://doi.org/10.1107/S0021889897005773.
Estermann, Michael A., et al. “A Helium Beam Path for an Imaging-Plate Detector System.” Journal of Applied Crystallography, vol. 1997, no. 30, 1997, pp. 1165–66, https://doi.org/10.1107/S0021889897005773.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.