Publication type: Article in scientific journal
Type of review: Peer review (publication)
Title: Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems
Authors: Scheidegger, Stephan
Estermann, Michael Alexander
Steurer, Steurer
DOI: 10.1107/S0021889899011929
Published in: Journal of Applied Crystallography
Volume(Issue): 33
Issue: 1
Page(s): 35
Pages to: 48
Issue Date: 2000
Publisher / Ed. Institution: Wiley
ISSN: 0021-8898
Language: German
Subjects: Aperiodic material; Diffuse scattering; Area detector systems; Image reconstruction
Subject (DDC): 540: Chemistry
Abstract: Methods for correcting specimen absorption in X-ray diffraction experiments, dedicated to two-dimensional area-detector systems and broad diffuse scattering phenomena, are implemented and tested. The respective transmission factors, in relation to the crystal or specimen shape, are applied to the intensity of every pixel of the two-dimensional detector. The pixel-wise approach allows for a fully quantitative treatment of continuous diffraction information, such as disorder diffuse scattering or scattering from amorphous materials, which is collected with a two-dimensional detector system. This is in contrast to routine data reduction, where the transmission factors are applied to the integrated Bragg intensities only. Furthermore, it is possible to assign different linear attenuation coefficients to the paths of the incident and scattered beams, as is desirable, for instance, in the case of X-ray holography with an internal resonant scatterer. Broad diffuse scattering data collected with synchrotron radiation and numerical calculations are used to study in detail the influence of experimental parameters on the accuracy of the pixel-wise absorption correction.
URI: https://digitalcollection.zhaw.ch/handle/11475/3534
Fulltext version: Published version
License (according to publishing contract): Licence according to publishing contract
Departement: School of Engineering
Appears in collections:Publikationen School of Engineering

Files in This Item:
There are no files associated with this item.
Show full item record
Scheidegger, S., Estermann, M. A., & Steurer, S. (2000). Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems. Journal of Applied Crystallography, 33(1), 35–48. https://doi.org/10.1107/S0021889899011929
Scheidegger, S., Estermann, M.A. and Steurer, S. (2000) ‘Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems’, Journal of Applied Crystallography, 33(1), pp. 35–48. Available at: https://doi.org/10.1107/S0021889899011929.
S. Scheidegger, M. A. Estermann, and S. Steurer, “Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems,” Journal of Applied Crystallography, vol. 33, no. 1, pp. 35–48, 2000, doi: 10.1107/S0021889899011929.
SCHEIDEGGER, Stephan, Michael Alexander ESTERMANN und Steurer STEURER, 2000. Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems. Journal of Applied Crystallography. 2000. Bd. 33, Nr. 1, S. 35–48. DOI 10.1107/S0021889899011929
Scheidegger, Stephan, Michael Alexander Estermann, and Steurer Steurer. 2000. “Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems.” Journal of Applied Crystallography 33 (1): 35–48. https://doi.org/10.1107/S0021889899011929.
Scheidegger, Stephan, et al. “Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems.” Journal of Applied Crystallography, vol. 33, no. 1, 2000, pp. 35–48, https://doi.org/10.1107/S0021889899011929.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.