Please use this identifier to cite or link to this item: https://doi.org/10.21256/zhaw-3257
Full metadata record
DC FieldValueLanguage
dc.contributor.authorErnst, Markus-
dc.contributor.authorSommer, Bettina-
dc.contributor.authorMeichtry, André-
dc.contributor.authorBauer, Christoph-
dc.date.accessioned2019-05-23T13:56:54Z-
dc.date.available2019-05-23T13:56:54Z-
dc.date.issued2019-
dc.identifier.issn1756-0500de_CH
dc.identifier.urihttps://digitalcollection.zhaw.ch/handle/11475/17149-
dc.description.abstractA reliable detection of bony landmarks of the spine is necessary in order to determine rigid bodies and to reduce the variability of marker placement in a movement laboratory setting. In a first study on the thoracic and lumbar spine, we demonstrated that placing markers on their relative positions between two major landmarks was superior to palpation of specific bony landmarks. The aims of this study were to examine the intra-rater reliability when palpating for spinous processes (SPs) of the second (C2) and seventh cervical vertebrae (C7), to determine the distances between C2 and C7 and the relative position of C7 along the length between C2 and the posterior superior iliac spine (PSIS) level.de_CH
dc.language.isoende_CH
dc.publisherBioMed Centralde_CH
dc.relation.ispartofBMC Research Notesde_CH
dc.rightshttp://creativecommons.org/licenses/by/4.0/de_CH
dc.subjectBony landmarkde_CH
dc.subjectCervical spinede_CH
dc.subjectReliabilityde_CH
dc.subjectSpinous processde_CH
dc.subject.ddc616.7: Krankheiten des Bewegungsapparates und Orthopädiede_CH
dc.titleIntra-rater reliability of determining positions of cervical spinous processes and measuring their relative distancesde_CH
dc.typeBeitrag in wissenschaftlicher Zeitschriftde_CH
dcterms.typeTextde_CH
zhaw.departementGesundheitde_CH
zhaw.organisationalunitInstitut für Physiotherapie (IPT)de_CH
dc.identifier.doi10.21256/zhaw-3257-
dc.identifier.doi10.1186/s13104-019-4299-8de_CH
dc.identifier.pmid31088571de_CH
zhaw.funding.euNode_CH
zhaw.issue265de_CH
zhaw.originated.zhawYesde_CH
zhaw.publication.statuspublishedVersionde_CH
zhaw.volume12de_CH
zhaw.publication.reviewPeer review (Publikation)de_CH
zhaw.funding.zhawValedo Nackentherapiede_CH
Appears in collections:Publikationen Gesundheit

Files in This Item:
File Description SizeFormat 
s13104-019-4299-8.pdf715.12 kBAdobe PDFThumbnail
View/Open
Show simple item record
Ernst, M., Sommer, B., Meichtry, A., & Bauer, C. (2019). Intra-rater reliability of determining positions of cervical spinous processes and measuring their relative distances. BMC Research Notes, 12(265). https://doi.org/10.21256/zhaw-3257
Ernst, M. et al. (2019) ‘Intra-rater reliability of determining positions of cervical spinous processes and measuring their relative distances’, BMC Research Notes, 12(265). Available at: https://doi.org/10.21256/zhaw-3257.
M. Ernst, B. Sommer, A. Meichtry, and C. Bauer, “Intra-rater reliability of determining positions of cervical spinous processes and measuring their relative distances,” BMC Research Notes, vol. 12, no. 265, 2019, doi: 10.21256/zhaw-3257.
ERNST, Markus, Bettina SOMMER, André MEICHTRY und Christoph BAUER, 2019. Intra-rater reliability of determining positions of cervical spinous processes and measuring their relative distances. BMC Research Notes. 2019. Bd. 12, Nr. 265. DOI 10.21256/zhaw-3257
Ernst, Markus, Bettina Sommer, André Meichtry, and Christoph Bauer. 2019. “Intra-Rater Reliability of Determining Positions of Cervical Spinous Processes and Measuring Their Relative Distances.” BMC Research Notes 12 (265). https://doi.org/10.21256/zhaw-3257.
Ernst, Markus, et al. “Intra-Rater Reliability of Determining Positions of Cervical Spinous Processes and Measuring Their Relative Distances.” BMC Research Notes, vol. 12, no. 265, 2019, https://doi.org/10.21256/zhaw-3257.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.