Please use this identifier to cite or link to this item:
https://doi.org/10.21256/zhaw-29481
Publication type: | Article in scientific journal |
Type of review: | Peer review (publication) |
Title: | Intra-rater reliability of hip abductor isometric strength testing in a standing position in older fallers and non-fallers |
Authors: | Bruyneel, Anne-Violette Gafner, Simone C. Ferrari, Serge Gold, Gabriel Monnin, Dominique Terrier, Philippe Bastiaenen, Caroline H. Allet, Lara |
et. al: | No |
DOI: | 10.1186/s11556-018-0198-6 10.21256/zhaw-29481 |
Published in: | European Review of Aging and Physical Activity |
Volume(Issue): | 15 |
Issue: | 9 |
Issue Date: | 2018 |
Publisher / Ed. Institution: | BioMed Central |
ISSN: | 1813-7253 1861-6909 |
Language: | English |
Subjects: | Abductor; Falls; Hip; Muscle strength; Older; Reliability; Standing |
Subject (DDC): | 613: Personal health |
Abstract: | Reduced hip muscle strength has been shown to be a major factor related to falls in older persons. However, comprehensive assessment of hip abduction strength in the clinical setting is challenging. The aim of this study was to investigate the feasibility and intra-rater reliability of a quick and simple hip abductor strength test in a functional standing position. |
URI: | https://digitalcollection.zhaw.ch/handle/11475/29481 |
Fulltext version: | Published version |
License (according to publishing contract): | CC BY 4.0: Attribution 4.0 International |
Departement: | School of Health Sciences |
Appears in collections: | Publikationen Gesundheit |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2018_Bruyneel-etal_Intra-rater-reliability-hip-abductor-strength-testing_BMC.pdf | 1.08 MB | Adobe PDF | View/Open |
Show full item record
Bruyneel, A.-V., Gafner, S. C., Ferrari, S., Gold, G., Monnin, D., Terrier, P., Bastiaenen, C. H., & Allet, L. (2018). Intra-rater reliability of hip abductor isometric strength testing in a standing position in older fallers and non-fallers. European Review of Aging and Physical Activity, 15(9). https://doi.org/10.1186/s11556-018-0198-6
Bruyneel, A.-V. et al. (2018) ‘Intra-rater reliability of hip abductor isometric strength testing in a standing position in older fallers and non-fallers’, European Review of Aging and Physical Activity, 15(9). Available at: https://doi.org/10.1186/s11556-018-0198-6.
A.-V. Bruyneel et al., “Intra-rater reliability of hip abductor isometric strength testing in a standing position in older fallers and non-fallers,” European Review of Aging and Physical Activity, vol. 15, no. 9, 2018, doi: 10.1186/s11556-018-0198-6.
BRUYNEEL, Anne-Violette, Simone C. GAFNER, Serge FERRARI, Gabriel GOLD, Dominique MONNIN, Philippe TERRIER, Caroline H. BASTIAENEN und Lara ALLET, 2018. Intra-rater reliability of hip abductor isometric strength testing in a standing position in older fallers and non-fallers. European Review of Aging and Physical Activity. 2018. Bd. 15, Nr. 9. DOI 10.1186/s11556-018-0198-6
Bruyneel, Anne-Violette, Simone C. Gafner, Serge Ferrari, Gabriel Gold, Dominique Monnin, Philippe Terrier, Caroline H. Bastiaenen, and Lara Allet. 2018. “Intra-Rater Reliability of Hip Abductor Isometric Strength Testing in a Standing Position in Older Fallers and Non-Fallers.” European Review of Aging and Physical Activity 15 (9). https://doi.org/10.1186/s11556-018-0198-6.
Bruyneel, Anne-Violette, et al. “Intra-Rater Reliability of Hip Abductor Isometric Strength Testing in a Standing Position in Older Fallers and Non-Fallers.” European Review of Aging and Physical Activity, vol. 15, no. 9, 2018, https://doi.org/10.1186/s11556-018-0198-6.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.