Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wand, Benedict Martin | - |
dc.contributor.author | Catley, Mark Jon | - |
dc.contributor.author | Luomajoki, Hannu Antero | - |
dc.contributor.author | O'Sulliva, Kieran James | - |
dc.contributor.author | Di Pietro, Flavia | - |
dc.contributor.author | O'Connell, Neil Edward | - |
dc.contributor.author | Moseley, G. Lorimer | - |
dc.date.accessioned | 2018-04-05T11:38:42Z | - |
dc.date.available | 2018-04-05T11:38:42Z | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 1356-689X | de_CH |
dc.identifier.uri | https://digitalcollection.zhaw.ch/handle/11475/4859 | - |
dc.description.abstract | A growing body of literature suggests that alterations in brain structure and function are a feature of chronic back pain. Tactile acuity is considered a clinical signature of primary somatosensory representation and offers a simple measure of cortical reorganisation. Clinical interpretation of test scores from an individual patient is hampered by variance in published normative values and less than ideal inter-rater reliability. These problems might be mitigated in people with unilateral back pain by using the patient as their own control and comparing tactile acuity at the painful site to performance at the corresponding position on the non-painful side. The first step in exploring this approach is to quantify the normal side-to-side difference in healthy populations. We pooled data from three previous studies that measured lumbar tactile acuity bilaterally in healthy controls using similar protocols. We calculated the mean and variance of the absolute error between sides, the standard error of measurement and the reliable change index (RCI). The mean difference between sides was 3.2 mm (±5.2) when assessed vertically and 1.9 mm (±3.2) when assessed horizontally. The standard error of measurement was 4.2 mm when assessed vertically and 2.7 mm when assessed horizontally. The RCI suggests that differences of greater than 13 mm when assessed horizontally and 17 mm when assessed vertically equate to 95% confidence that a difference truly exists. Several assumptions related to the application of this approach need to be investigated further. | de_CH |
dc.language.iso | en | de_CH |
dc.publisher | Elsevier | de_CH |
dc.relation.ispartof | Manual Therapy | de_CH |
dc.rights | Licence according to publishing contract | de_CH |
dc.subject | Chronic low back pain | de_CH |
dc.subject | Two-point discrimination | de_CH |
dc.subject | Sensory acuity | de_CH |
dc.subject | Body image | de_CH |
dc.subject.ddc | 617.5: Orthopädische Chirurgie | de_CH |
dc.title | Lumbar tactile acuity is near identical between sides in healthy pain-free participants | de_CH |
dc.type | Beitrag in wissenschaftlicher Zeitschrift | de_CH |
dcterms.type | Text | de_CH |
zhaw.departement | Gesundheit | de_CH |
zhaw.organisationalunit | Institut für Physiotherapie (IPT) | de_CH |
dc.identifier.doi | 10.1016/j.math.2014.01.002 | de_CH |
zhaw.funding.eu | No | de_CH |
zhaw.issue | 5 | de_CH |
zhaw.originated.zhaw | Yes | de_CH |
zhaw.pages.end | 507 | de_CH |
zhaw.pages.start | 504 | de_CH |
zhaw.publication.status | publishedVersion | de_CH |
zhaw.volume | 19 | de_CH |
zhaw.publication.review | Peer review (Publikation) | de_CH |
Appears in collections: | Publikationen Gesundheit |
Files in This Item:
There are no files associated with this item.
Show simple item record
Wand, B. M., Catley, M. J., Luomajoki, H. A., O’Sulliva, K. J., Di Pietro, F., O’Connell, N. E., & Moseley, G. L. (2014). Lumbar tactile acuity is near identical between sides in healthy pain-free participants. Manual Therapy, 19(5), 504–507. https://doi.org/10.1016/j.math.2014.01.002
Wand, B.M. et al. (2014) ‘Lumbar tactile acuity is near identical between sides in healthy pain-free participants’, Manual Therapy, 19(5), pp. 504–507. Available at: https://doi.org/10.1016/j.math.2014.01.002.
B. M. Wand et al., “Lumbar tactile acuity is near identical between sides in healthy pain-free participants,” Manual Therapy, vol. 19, no. 5, pp. 504–507, 2014, doi: 10.1016/j.math.2014.01.002.
WAND, Benedict Martin, Mark Jon CATLEY, Hannu Antero LUOMAJOKI, Kieran James O’SULLIVA, Flavia DI PIETRO, Neil Edward O’CONNELL und G. Lorimer MOSELEY, 2014. Lumbar tactile acuity is near identical between sides in healthy pain-free participants. Manual Therapy. 2014. Bd. 19, Nr. 5, S. 504–507. DOI 10.1016/j.math.2014.01.002
Wand, Benedict Martin, Mark Jon Catley, Hannu Antero Luomajoki, Kieran James O’Sulliva, Flavia Di Pietro, Neil Edward O’Connell, and G. Lorimer Moseley. 2014. “Lumbar Tactile Acuity Is near Identical between Sides in Healthy Pain-Free Participants.” Manual Therapy 19 (5): 504–7. https://doi.org/10.1016/j.math.2014.01.002.
Wand, Benedict Martin, et al. “Lumbar Tactile Acuity Is near Identical between Sides in Healthy Pain-Free Participants.” Manual Therapy, vol. 19, no. 5, 2014, pp. 504–7, https://doi.org/10.1016/j.math.2014.01.002.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.