Please use this identifier to cite or link to this item:
https://doi.org/10.21256/zhaw-3558
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Scheidegger, Stephan | - |
dc.contributor.author | Füchslin, Rudolf Marcel | - |
dc.date.accessioned | 2018-03-21T12:28:13Z | - |
dc.date.available | 2018-03-21T12:28:13Z | - |
dc.date.issued | 2011 | - |
dc.identifier.isbn | 978-3-905745-44-3 | de_CH |
dc.identifier.uri | https://digitalcollection.zhaw.ch/handle/11475/4141 | - |
dc.description.abstract | The response of tumours onto ionizing radiation cannot be fully understood by commonly used radiobiological models. The reason may lie in the complex structure of the cellular systems which show a high degree of compartmentalisation and which is characterised by a network of interacting processes at different time scales. To access the dynamic response of cells onto radiation, compartmental models based on a biological dose equivalent can be used. Two different models (T-LQ- and T-IR-model) are used to fit experimental data of the clonogenic survival of irradiated cells at very high dose rates. The models reveal the correct dose rate dependence over a wide range of the parameter space when adapting the kinetic constants to the dose rate. This adaption could be an indication for the multi-scale structure of the system. | de_CH |
dc.language.iso | en | de_CH |
dc.publisher | Arbeitsgemeinschaft Simulation | de_CH |
dc.rights | Licence according to publishing contract | de_CH |
dc.subject | Radiation | de_CH |
dc.subject | Radiobiology | de_CH |
dc.subject | Emergence | de_CH |
dc.subject | Dose equivalent | de_CH |
dc.subject.ddc | 615: Pharmakologie und Therapeutik | de_CH |
dc.title | Kinetic model for dose equivalent : an efficient way to predict systems response of irradiated cells | de_CH |
dc.type | Konferenz: Paper | de_CH |
dcterms.type | Text | de_CH |
zhaw.departement | School of Engineering | de_CH |
dc.identifier.doi | 10.21256/zhaw-3558 | - |
zhaw.conference.details | 21. Symposium Simulationstechnik (ASIM 2011), Winterthur, 7-9 September 2011 | de_CH |
zhaw.funding.eu | No | de_CH |
zhaw.originated.zhaw | Yes | de_CH |
zhaw.parentwork.editor | Bödi, Richard | - |
zhaw.parentwork.editor | Maurer, Werner | - |
zhaw.publication.status | publishedVersion | de_CH |
zhaw.publication.review | Peer review (Abstract) | de_CH |
zhaw.title.proceedings | Proceedings of ASIM 2011 : Grundlagen, Methoden und Anwendungen in Modellbildung und Simulation | de_CH |
Appears in collections: | Publikationen School of Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2011_Scheidegger_Kinetic model_ASIM.pdf | 90.04 kB | Adobe PDF | View/Open |
Show simple item record
Scheidegger, S., & Füchslin, R. M. (2011). Kinetic model for dose equivalent : an efficient way to predict systems response of irradiated cells [Conference paper]. In R. Bödi & W. Maurer (Eds.), Proceedings of ASIM 2011 : Grundlagen, Methoden und Anwendungen in Modellbildung und Simulation. Arbeitsgemeinschaft Simulation. https://doi.org/10.21256/zhaw-3558
Scheidegger, S. and Füchslin, R.M. (2011) ‘Kinetic model for dose equivalent : an efficient way to predict systems response of irradiated cells’, in R. Bödi and W. Maurer (eds) Proceedings of ASIM 2011 : Grundlagen, Methoden und Anwendungen in Modellbildung und Simulation. Arbeitsgemeinschaft Simulation. Available at: https://doi.org/10.21256/zhaw-3558.
S. Scheidegger and R. M. Füchslin, “Kinetic model for dose equivalent : an efficient way to predict systems response of irradiated cells,” in Proceedings of ASIM 2011 : Grundlagen, Methoden und Anwendungen in Modellbildung und Simulation, 2011. doi: 10.21256/zhaw-3558.
SCHEIDEGGER, Stephan und Rudolf Marcel FÜCHSLIN, 2011. Kinetic model for dose equivalent : an efficient way to predict systems response of irradiated cells. In: Richard BÖDI und Werner MAURER (Hrsg.), Proceedings of ASIM 2011 : Grundlagen, Methoden und Anwendungen in Modellbildung und Simulation. Conference paper. Arbeitsgemeinschaft Simulation. 2011. ISBN 978-3-905745-44-3
Scheidegger, Stephan, and Rudolf Marcel Füchslin. 2011. “Kinetic Model for Dose Equivalent : An Efficient Way to Predict Systems Response of Irradiated Cells.” Conference paper. In Proceedings of ASIM 2011 : Grundlagen, Methoden Und Anwendungen in Modellbildung Und Simulation, edited by Richard Bödi and Werner Maurer. Arbeitsgemeinschaft Simulation. https://doi.org/10.21256/zhaw-3558.
Scheidegger, Stephan, and Rudolf Marcel Füchslin. “Kinetic Model for Dose Equivalent : An Efficient Way to Predict Systems Response of Irradiated Cells.” Proceedings of ASIM 2011 : Grundlagen, Methoden Und Anwendungen in Modellbildung Und Simulation, edited by Richard Bödi and Werner Maurer, Arbeitsgemeinschaft Simulation, 2011, https://doi.org/10.21256/zhaw-3558.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.